SYNCHRONISATION ERROR DRIVE MODULE Ax

Servo Bus Communication Error

Kuka · KR C2 Robot Controller

Was bedeutet SYNCHRONISATION ERROR DRIVE MODULE Ax ?

The maximum permissible number of communication errors with the servo bus for the specified axis (Ax) has been exceeded. Too many consecutive toggle bit errors are a common cause, leading to short-circuit braking.

Häufige Ursachen

  • Loss of communication on the servo bus (e.g., EtherCAT, Profinet).
  • Incorrect network configuration or cabling for the servo drive.
  • Faulty drive module or controller interfering with bus traffic.
  • Synchronization offset exceeding allowed limits (P5-01).

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the Interbus cable connections between the DSE, KPS, and all KSD modules for integrity and proper seating.