HEAT SINK TEMPERATURE Ax
Axis Heat Sink Overtemperature
Kuka · KR C2 Robot Controller
Was bedeutet HEAT SINK TEMPERATURE Ax ?
An overtemperature condition has been detected on the heat sink of the servo drive module for the specified axis (Ax). This indicates inadequate cooling or excessive load on the axis.
Häufige Ursachen
- Ambient temperature in the cabinet is too high.
- Insufficient cooling for the drive's heat sink (blocked vents, fan failure).
- Drive operating at peak load for extended periods.
- Oversized motor or drive operating inefficiently.
- Faulty temperature sensor on the heat sink (P6-01).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the cabinet cooling circuit and fans for proper operation and airflow.
- 2
Reduce the load on the affected axis by decreasing the Override (OVR) setting in the robot program.
- 3
Reduce the velocity for the affected axis using the `$VEL_AXIS` parameter.
- 4
Reduce the acceleration for the affected axis using the `$ACC_AXIS` parameter.