Übersetzen...
Cabinet temperature too high PMx

KPS Interior Overtemperature

Kuka · KR C2 Robot Controller

Was bedeutet Cabinet temperature too high PMx ?

An overtemperature condition has been detected inside the KPS module (PMx). This indicates that the cabinet ventilation is not functioning correctly, leading to an elevated interior temperature affecting the KPS.

Häufige Ursachen

  • Ambient temperature within the control cabinet is excessive.
  • Cabinet cooling system (fans, filters) is inadequate or malfunctioning.
  • External heat sources impacting the cabinet temperature.
  • High power dissipation from internal components.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the cabinet ventilation system for proper operation and sufficient airflow.

  2. 2

    Verify that cabinet air filters are clean and not obstructed.

Alle Codes in diesem Handbuch durchsuchen (58)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes