52 Drive Forward Coil Fault

Kone · Elevator Control

Was bedeutet 52 ?

A fault has been detected in the drive forward coil, indicating an electrical issue with the solenoid responsible for forward motion. This disables both lifting and driving functions.

Häufige Ursachen

  • Drive forward coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the drive forward coil.
  • Control circuit failure attempting to activate the coil.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the control voltage supply to the drive forward coil circuit at the respective terminals.

  2. 2

    Inspect all wiring and connections to the drive forward coil for looseness, damage, or corrosion.

  3. 3

    Measure the resistance of the drive forward coil across its terminals and compare with specified values (refer to equipment manual) to detect open or short circuits.

  4. 4

    Check the output signal from the elevator control system intended for the drive forward coil during a forward motion command.