BATTERY LOW
Kone · Elevator Control
Was bedeutet 1066 ?
The motor controller (codes 1066, 2066, 3066) has detected a low battery voltage condition. This indicates insufficient power supply to the drive system. The specific lift reaction is controller dependent.
Häufige Ursachen
- Battery significantly discharged below operational threshold.
- Aging battery with reduced capacity.
- High current draw exceeding battery's instantaneous capability.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Measure the voltage of the motor controller's backup battery pack and compare against manufacturer specifications.
- 2
Inspect all battery terminals, connectors, and associated cabling for corrosion, damage, or loose connections.
- 3
Verify the output voltage and charging current from the dedicated battery charging circuit to the battery pack.
- 4
Check the main input power supply voltage at the motor controller (drive system) terminals and confirm it is within specified limits.