106

BMS Fault

Kone · Elevator Control

Was bedeutet 106 ?

A critical fault has been detected by the Battery Management System (BMS), indicating a severe issue with the battery or its management. This fault disables all motion functions.

Häufige Ursachen

  • Critical fault detected by the BMS, potentially related to battery cells, temperature, or communication failure.
  • Internal failure within the BMS module.
  • Serious battery voltage, current, or temperature condition.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Measure the battery voltage at the terminals of the BMS unit to confirm it is within the specified operating range.

  2. 2

    Inspect all wiring and connectors between the battery, the BMS module, and the main elevator control board for loose connections, corrosion, or physical damage.

  3. 3

    Verify the input supply voltage to the BMS charging circuit or the dedicated battery charger to ensure proper power delivery for battery maintenance.

  4. 4

    Check the BMS diagnostic indicators or the elevator control panel's fault log for any specific sub-codes or additional information related to the BMS fault.