103

Battery is draining

Kone · Elevator Control

Was bedeutet 103 ?

The battery is currently experiencing a discharge event. This is a warning only, indicating that power is being drawn from the battery.

Häufige Ursachen

  • Normal battery discharge during machine operation.
  • Unexpected discharge current when machine should be idle (parasitic load).
  • Charger not active or charging at an insufficient rate during operation.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the presence and stability of the main AC power supply to the Kone Elevator Control system, ensuring no intermittent power loss.

  2. 2

    Measure the battery charging voltage and current at the battery terminals to confirm proper function of the charging circuit.

  3. 3

    Inspect battery terminals, wiring, and connections for any signs of corrosion, damage, or looseness.

  4. 4

    Check Kone Elevator Control system parameters related to battery management, such as charging setpoints and discharge thresholds, against manufacturer specifications.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026