68

Doors Obstructed

Kone · Electric Traction Elevators

Was bedeutet 68 ?

The KONE LCE W/KDM elevator doors are prevented from closing completely, activating a safety interlock. This condition will inhibit elevator movement until the obstruction is cleared.

Häufige Ursachen

  • Physical object (e.g., debris, person, item) blocking the door path.
  • Damage to door tracks or rollers impeding smooth door operation.
  • Activation of the door safety edge or light curtain sensor.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Visually inspect the elevator door opening and both door tracks for any foreign objects.

  2. 2

    Carefully remove any detected obstructions from the door path or tracks.

  3. 3

    Verify that the door safety edge or light curtain sensors are clean, undamaged, and correctly aligned.