Übersetzen...
F7031

Incorrect direction of motion

Indramat · Indradrive

Was bedeutet F7031 ?

The motor attempted to move in a direction opposite to the allowed or commanded direction during a safety-monitored operation. This fault indicates a serious discrepancy between the expected and actual motion, usually triggered by a safety function like Safe Direction.

Häufige Ursachen

  • Incorrect phase sequence of motor wiring.
  • Inverted encoder signals or incorrect encoder wiring.
  • Incorrectly configured safety direction parameter.
  • Control error or unintended command causing reverse motion.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the motor phase connections (U, V, W) to ensure correct rotation direction relative to commands.

  2. 2

    Check the encoder wiring for correct polarity and signal integrity; ensure signals are not inverted.

  3. 3

    Review the safety direction configuration parameters in the IndraDrive and ensure they match the application's requirements.

  4. 4

    Test the motor's actual direction of rotation against a commanded positive and negative movement in a controlled environment.

  5. 5

    If the problem persists, the drive's control of direction or its interpretation of encoder feedback might be faulty.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes