Übersetzen...
F7014

Acceleration threshold exceeded

Indramat · Indradrive

Was bedeutet F7014 ?

The motor's actual acceleration has exceeded a safety-related acceleration threshold. This fault is triggered by safety monitoring functions (e.g., Safe Acceleration Monitoring) to ensure that the axis does not accelerate faster than what is considered safe for the application, preventing sudden, uncontrolled movements.

Häufige Ursachen

  • Uncontrolled or unexpected rapid acceleration of the axis.
  • Incorrectly configured safety-related acceleration threshold parameter (e.g., S-0-0XXX Safe Acceleration Threshold).
  • Faulty position/speed feedback causing erroneous acceleration calculation.
  • External forces causing rapid changes in motor speed.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the configured safety-related acceleration threshold parameter in the IndraDrive against the safety requirements.

  2. 2

    Check the motor encoder for correct operation, secure mounting, and reliable position/speed signal output.

  3. 3

    Review the motion control program for any commands that might cause rapid, unintended acceleration.

  4. 4

    Inspect for mechanical issues such as loose couplings or sudden load changes that could induce high acceleration.

  5. 5

    Re-tune the drive's acceleration and deceleration ramp parameters to ensure smooth and controlled motion within safe limits.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes