Safety rel. position limit val., exc. in neg. dir.
Indramat · Indradrive
Was bedeutet F7012 ?
The motor's actual position has exceeded a defined safety-related position limit in the negative direction. This fault, part of safe motion monitoring, prevents the axis from moving beyond a safe physical boundary in the reverse direction.
Häufige Ursachen
- Uncontrolled or unintended movement beyond the negative safety limit.
- Incorrectly configured safety-related negative position limit parameter.
- Faulty position feedback (encoder) providing erroneous actual position values.
- Mechanical overrun due to excessive inertia or braking distance.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the configured safety-related negative position limit parameter (e.g., S-0-0XXX Safe Negative Position Limit) in the IndraDrive.
- 2
Check for any mechanical issues that could cause the axis to overshoot its intended position, such as worn brakes or excessive play.
- 3
Inspect the position encoder and its cabling for proper function and signal integrity.
- 4
Review the motion control program for unintended commands or logic errors that might cause overtravel.
- 5
Adjust deceleration ramps or braking parameters if the axis consistently overshoots due to inertia.