Übersetzen...
E2819

Mains failure

Indramat · IndraDrive MPx02

Was bedeutet E2819 ?

The IndraDrive MPx02 has detected a complete loss of the incoming AC mains power supply. This means the drive is no longer receiving power from the grid and will initiate a controlled shutdown or ride-through sequence based on its configuration, as it cannot sustain operation.

Häufige Ursachen

  • Main circuit breaker tripped or fuse blown for the entire system supplying the drive.
  • Emergency stop activated cutting off main power to the machine.
  • Power utility outage affecting the facility or a section of the plant.
  • Complete disconnection of the mains power cable to the drive.
  • Fault in the upstream power supply or distribution system.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the main circuit breaker or fuses supplying power to the entire machine or system for the IndraDrive MPx02 and restore power if tripped/blown.

  2. 2

    Verify that no emergency stop button or safety interlock has been activated, which would cut off mains power.

  3. 3

    Measure the incoming AC mains voltage at the drive's input terminals (L1, L2, L3) to confirm the complete absence of voltage.

  4. 4

    Inspect the mains power cable for any physical damage or disconnections.

  5. 5

    Contact the power utility or check the building's main electrical panel if the entire plant or section is without power.

Alle Codes in diesem Handbuch durchsuchen (56)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes