Acceleration of master axis generator is zero
Indramat · IndraDrive MPx02
Was bedeutet E2101 ?
The IndraDrive MPx02 has detected that the acceleration commanded by the master axis generator is zero. In some motion control scenarios, especially those involving dynamic following, a zero acceleration from the master can indicate an unexpected or incorrect master motion profile, potentially leading to issues for slave axes.
Häufige Ursachen
- The master axis generator is providing a constant velocity command with no acceleration, which may be unexpected or inconsistent with the current motion phase.
- An error in the master's motion profile generation, resulting in zero acceleration when acceleration is expected during a profile segment.
- The master axis has completed its acceleration phase and is now at constant velocity, but this warning indicates it's an unexpected state for the slave.
- Incorrect parameterization of acceleration monitoring between master and slave.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review the motion profile or program being executed by the master axis generator to ensure it is correctly generating acceleration commands for the current motion phase.
- 2
Verify the parameters related to acceleration and jerk limits in both the master axis and the IndraDrive MPx02 (slave axis) to ensure coordinated operation.
- 3
Check if the master axis is operating in a mode that intentionally commands zero acceleration, and if so, confirm that this is acceptable for the application and the slave's reaction.
- 4
If the master axis is expected to accelerate, troubleshoot the master controller or motion generator for issues in its profile calculation or command generation.