Übersetzen...
E2079

Absolute enc. monitoring, measuring encoder (encoder alarm)

Indramat · IndraDrive MPx02

Was bedeutet E2079 ?

An alarm condition has been detected by the IndraDrive MPx02 from the absolute measuring encoder (often a linear scale or external rotary encoder directly monitoring the load). This indicates a problem with the primary absolute position feedback for the machine's actual position, impacting precision, homing, and safety functions.

Häufige Ursachen

  • Loss of absolute position data from the measuring encoder (e.g., battery failure, memory corruption).
  • Internal fault within the absolute measuring encoder itself.
  • Communication error between the drive and the absolute measuring encoder.
  • Incorrect measuring encoder parameterization in the drive for the specific encoder type or resolution.
  • Mechanical damage or misalignment of the measuring encoder relative to the axis.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the absolute measuring encoder's status indicators (LEDs) for any error codes or abnormal behavior according to its manual.

  2. 2

    Verify the communication wiring and protocol settings between the IndraDrive MPx02 and the absolute measuring encoder, ensuring robust connection.

  3. 3

    If the measuring encoder uses a battery for absolute position retention (e.g., multi-turn rotary), check its voltage and replace it if necessary.

  4. 4

    Ensure that the absolute measuring encoder parameters in the drive are correctly configured for the specific encoder type, resolution, and mounting orientation.

  5. 5

    Attempt a re-initialization of the absolute position or a reference run if the absolute position data has been lost, and if the alarm persists, consider replacing the absolute measuring encoder.

Alle Codes in diesem Handbuch durchsuchen (56)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes