Übersetzen...
E264
Target Position Out of Range
Indramat · ECODRIVE Controller
Was bedeutet E264 ?
When using the 'command controlled operation' mode, the target position of the selected additive process block is verified. This warning occurs if the target position lies outside the represented or permissible travel range for the ECODRIVE DKC01.1/DKC11.1 drive.
Häufige Ursachen
- The target position is incorrectly set or falls outside the allowed travel range for the axis.
- Incorrect scaling or modulo settings for position data in the ECODRIVE DKC01.1/DKC11.1 controller.
- Software limit switches or travel limits are configured too restrictively.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the target position parameter and correct it to be within the valid range for the axis.
- 2
Select the position data display channel in modulo format if the application requires cyclical positioning.
- 3
Verify the configured software limit switches in the ECODRIVE DKC01.1/DKC11.1 controller parameters.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Indramat ECODRIVE Controller