Monitoring Safe Halt
Indramat · CLM01.3-M Flying Cutoff Control
Was bedeutet F501 ?
The safety function Safe Halt is selected, but the drive interlock is not active, or the control has given the drive enable. This indicates a discrepancy in the safety circuit state, where the drive is enabled despite Safe Halt being active or the interlock being open.
Häufige Ursachen
- Error in the actuation of the drive interlock (Indramat DIAX04 SSE-03VRS: connector X3).
- Malfunction of the control system, sending an incorrect drive enable signal.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
De-energize the system. Inspect the wiring of the drive interlock circuit, specifically at the Indramat DIAX04 SSE-03VRS connector X3, for loose connections, damage, or incorrect termination.
- 2
Verify the state of the drive interlock inputs to the Indramat DIAX04 SSE-03VRS drive controller using diagnostic tools or status indicators, ensuring they reflect the expected safety state (e.g., inactive when Safe Halt is selected).
- 3
Check the status of the drive enable signal from the control system. Ensure that the control is not commanding drive enable while Safe Halt is active.
- 4
Consult the control system's diagnostics and event logs for any errors or unexpected commands related to drive enable or safety functions.
- 5
If the issue persists and appears to originate from the control system's logic or hardware, contact the control system manufacturer for further assistance.