Error during phase regression
Indramat · CLM01.3-M Flying Cutoff Control
Was bedeutet F405 ?
Switching back from a communication phase did not result in a switch to phase 0, indicating a malfunction in the SERCOS master module of the controller connected to the Indramat DIAX04 SSE-03VRS drive.
Häufige Ursachen
- Malfunction in the SERCOS master module of the controller.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the SERCOS communication configuration parameters in the master controller for any incorrect or conflicting settings.
- 2
Check the status and diagnostic LEDs on the SERCOS master module for specific error indications that might point to its internal state.
- 3
Ensure the master controller's firmware is up-to-date and compatible with the Indramat DIAX04 SSE-03VRS drive controllers.
- 4
If possible, attempt to reinitialize the SERCOS communication ring from the master controller's interface.
- 5
If the issue persists, the SERCOS master module itself may be defective and require further investigation or replacement by the control system manufacturer.