Diagnostic message power supply erroneous
Indramat · CLM01.3-M Flying Cutoff Control
Was bedeutet E353 ?
The Indramat HVE or HVR power supply unit cyclically sends status and error messages via a serial connection to the connected controller (DIAX04 SSE-03VRS). This warning is generated if the controller does not receive several sequential messages, indicating a communication breakdown.
Häufige Ursachen
- The serial interface of the power supply unit (HVE/HVR) is defective.
- A break or damage in the serial connection lines (bus cable) between the power supply unit and the controller.
- The serial interface of the controller (DIAX04 SSE-03VRS) is defective.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Visually inspect the serial bus cable connecting the HVE/HVR power supply unit to the DIAX04 SSE-03VRS controller for any signs of damage or loose connections.
- 2
Check the termination and continuity of the bus cable, and replace it if necessary.
- 3
If the bus cable and connections are verified, consider replacing the HVE/HVR power supply unit if its serial interface is suspected to be defective.
- 4
If the fault persists after checking the cable and power supply, the serial interface of the DIAX04 SSE-03VRS controller may be defective, requiring controller replacement.