Safety input signals wrong, checksum
Indramat · DIAX 04
Was bedeutet F507 ?
The DIAX04 SSE-03VRS drive's safety module detected a checksum error in the received safety input signals. This means the integrity of the safety-related data transmitted from an external safety device (e.g., safety PLC) or across internal channels is compromised. This is a critical safety fault, as the drive cannot trust the received safety commands.
Häufige Ursachen
- Corrupted safety data telegram due to electromagnetic interference on the safety communication link.
- Faulty external safety PLC or safety communication module transmitting incorrect checksums.
- Damage or poor shielding on the safety communication cable to the DIAX04 SSE-03VRS drive.
- Internal fault within the DIAX04 SSE-03VRS drive's safety module that calculates or checks checksums.
- Mismatched safety communication protocols or versions between the external device and the DIAX04 SSE-03VRS.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the safety communication link (e.g., Profisafe, F-Link) cabling for damage, proper shielding, and termination.
- 2
Verify the status and diagnostic logs of the external safety PLC or safety communication module for any errors.
- 3
Ensure that the safety communication protocol and configuration parameters are identical and compatible between the external safety device and the DIAX04 SSE-03VRS drive.
- 4
Check for sources of excessive electromagnetic interference near the safety communication cables.
- 5
Perform a full power cycle of the DIAX04 SSE-03VRS system and the external safety device. If the fault persists, consider a faulty safety communication interface on the drive.