2086

External Fan Abnormal

Huawei · SUN2000 Solar Inverter

Was bedeutet 2086 ?

An external fan (FAN 1-3) is experiencing an abnormality such as a short circuit, insufficient power supply, or a blocked air channel. This Major alarm indicates inadequate cooling for the inverter, which can lead to overheating.

Häufige Ursachen

  • The external fan is short-circuited.
  • The power supply for the external fan is insufficient.
  • The air channel for the external fan is blocked.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Shut down the fan.

  2. 2

    Turn off the DC switch.

  3. 3

    Check whether the fan blades are damaged and clear any foreign matter around the fan.

  4. 4

    Reinstall the fan.

  5. 5

    Turn on the DC switch.

  6. 6

    If the fault persists after 15 minutes, replace the external fan.

Alle Codes in diesem Handbuch durchsuchen (33)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026