2001
High string input voltage
Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter
Was bedeutet 2001 ?
The PV array is not properly configured, with too many PV modules connected in series, causing the PV string open-circuit voltage to exceed the maximum SUN2000 operating voltage. This can damage the inverter.
Häufige Ursachen
- Excessive PV modules are connected in series to the PV string; therefore the PV string open-circuit voltage exceeds the maximum SUN2000 operating voltage.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Reduce the number of PV modules connected in series to the PV string until the PV string open-circuit voltage is less than or equal to the maximum SUN2000 operating voltage.