Übersetzen...
231-A005

Controller unit not suited for FS

Heidenhain · TNC CNC Controllers

Was bedeutet 231-A005 ?

This warning indicates that the control unit (CC, UEC, UMC) is not suitable for control systems requiring functional safety (FS), as detected during a check of the safety kernel software SKERN-CC. The currently installed controller unit fulfills safety requirements according to EN 13849 but is not approved for functional safety applications.

Häufige Ursachen

  • The installed controller unit (CC, UEC, UMC) is not approved for functional safety applications.
  • Incorrect controller unit type or version installed for an application requiring functional safety (FS).
  • Mismatched hardware configuration with the safety kernel software (SKERN-CC) requirements.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the part number and type of the installed controller unit (CC, UEC, UMC) against the machine's functional safety requirements.

  2. 2

    Replace the affected controller unit (CC, UEC, UMC) with a model explicitly approved for functional safety (FS).

  3. 3

    Consult the machine documentation or Heidenhain technical support to confirm the correct controller unit required for your system's safety integrity level.

Alle Codes in diesem Handbuch durchsuchen (47)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes