CC limit switch %.1s+
Heidenhain · NC Control
Was bedeutet 7950 A800 ?
The permissible positive range of traverse for the specified axis was exceeded. This indicates the axis has moved beyond its programmed positive software limit or a physical positive limit switch has been activated.
Häufige Ursachen
- Permissible positive range of traverse exceeded.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the physical positive limit switch for the affected axis for any damage, obstruction, or incorrect adjustment.
- 2
Verify the setting of parameter MP650 (Positive software limit switch) for the specified axis to ensure it is configured correctly according to the machine's travel limits.
- 3
Inspect the axis position feedback system (encoder) for accuracy and potential errors that could lead to an overshoot.
- 4
Manually jog the axis cautiously in the negative direction to move it off the limit switch, then verify it moves freely without mechanical binding before reaching the positive limit again.