5635

Channel %d cannot be displayed

Heidenhain · NC Control

Was bedeutet 5635 ?

More than four channels per controller board have been selected for display. The system has a limitation of four channels per controller board, leading to this display error.

Häufige Ursachen

  • More than four channels per controller board selected.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Access the display configuration settings of the NC control.

  2. 2

    Identify which channels are currently selected for display on the affected controller board.

  3. 3

    Deselect any channels beyond the maximum limit of four (e.g., channel 5 or 6).

  4. 4

    Save the new display configuration and restart the display function or the NC control if necessary.