2211

No TOOL CALL permitted with M128

Heidenhain · NC Control

Was bedeutet 2211 ?

A TOOL CALL command is not permitted when M128 (tool radius compensation active) is currently active. This is a program execution restriction to prevent conflicts with tool path calculations.

Häufige Ursachen

  • A TOOL CALL is not permitted with M128 active.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Before attempting a TOOL CALL, ensure that M128 (tool radius compensation) is deactivated.

  2. 2

    Insert the M129 command in the NC program to cancel M128 prior to the TOOL CALL command.

  3. 3

    Verify the sequence of NC commands to ensure M128 is not accidentally activated or left active when a TOOL CALL is required.

  4. 4

    Review the machining program to understand why M128 is active and if it's being correctly managed in the sequence of operations.