%.1s motor encoder freq. too high
Heidenhain · NC Control
Was bedeutet 2208 F2A0 ?
The input frequency of the motor encoder for the displayed axis is incorrect, specifically too high. This can lead to erroneous speed and position feedback.
Häufige Ursachen
- Input frequency of the motor encoder for the displayed axis is incorrect.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Use an oscilloscope to measure the actual input frequency of the motor encoder signal at the NC control's input terminal for the affected axis.
- 2
Compare the measured frequency to the expected maximum frequency specified in the motor/encoder or NC control manual.
- 3
Inspect the motor encoder cable for any signs of damage, poor shielding, or external interference that could generate erroneous high-frequency signals.
- 4
Verify that the encoder and the NC control's input stage are compatible in terms of maximum operating frequency and signal type.