Übersetzen...
2203 F200

%.1s motor enc. zn ampl. too small

Heidenhain · NC Control

Was bedeutet 2203 F200 ?

The ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small. This indicates a problem with the encoder signal integrity, potentially leading to inaccurate position feedback.

Häufige Ursachen

  • ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the motor encoder (ERN 1381) cabling for the specified axis, including shielding and ground connections, for damage, loose contacts, or interference.

  2. 2

    Inspect the encoder itself for signs of physical damage, contamination (e.g., oil, dust), or mounting issues that could affect signal generation.

  3. 3

    Verify the power supply voltage to the encoder is present and stable, within the specified operating range.

  4. 4

    If possible, use an oscilloscope to measure the ZN signal amplitude directly at the encoder output and at the control input to detect signal degradation.

Alle Codes in diesem Handbuch durchsuchen (58)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes