Übersetzen...
2198 F180

Axis %.1s: MP2340/MP2350 incorrect

Heidenhain · NC Control

Was bedeutet 2198 F180 ?

Parameters MP2340 and/or MP2350 for the displayed axis are incorrect. This indicates a configuration mismatch for specific machine parameters related to the axis.

Häufige Ursachen

  • MP2340 parameter for the displayed axis is incorrect.
  • MP2350 parameter for the displayed axis is incorrect.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Identify the specific function of parameters MP2340 and MP2350 for the affected axis by consulting the Heidenhain parameter manual.

  2. 2

    Verify the current settings of MP2340 and MP2350 against the machine's configuration backup or factory default values for that axis.

  3. 3

    Correct any discrepancies in the parameter settings to match the machine's specified configuration.

  4. 4

    If parameters appear correct, investigate for underlying software issues or hardware faults affecting parameter storage or retrieval.

Alle Codes in diesem Handbuch durchsuchen (58)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes