Übersetzen...
2197 F170

Motor %.1s: n-max incorrect

Heidenhain · NC Control

Was bedeutet 2197 F170 ?

The N-MAX (maximum rotational speed) of the motor for the displayed axis is incorrect. This means the configured maximum speed in the NC control does not align with the motor's design limit or the application's allowed speed range.

Häufige Ursachen

  • N-MAX (maximum rotational speed) parameter for the motor on the displayed axis is incorrectly configured.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the motor's maximum rotational speed parameter setting (N-MAX) for the specified axis against the motor nameplate data.

  2. 2

    Check the mechanical integrity of the axis, including bearings, couplings, and guides, for any issues that might restrict or impede speed.

  3. 3

    Review the application's speed requirements to ensure they are within the motor's specified limits and the drive's capabilities.

  4. 4

    Inspect the motor encoder for proper function and accurate feedback, as incorrect speed sensing can lead to this error.

Alle Codes in diesem Handbuch durchsuchen (58)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes