Smart Meter Communication
Fronius · Symo Advanced
Was bedeutet 702 ?
This status code indicates a communication error with the Smart Meter connected to the Fronius Primo GEN24 208-240 inverter. This typically results from loose or incorrect wiring, improper Smart Meter configuration (e.g., Modbus address), or a defective Smart Meter itself, preventing accurate energy flow measurement.
Häufige Ursachen
- Loose, incorrect, or damaged communication wiring (e.g., RS485) between the inverter and the Smart Meter.
- Incorrect Smart Meter configuration, such as an incorrect Modbus address or other communication settings within the inverter parameters.
- The Smart Meter device itself is defective and unable to communicate.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the communication wiring (e.g., A/B lines for RS485) between the inverter and the Smart Meter for proper connection, polarity, and continuity.
- 2
Verify the Smart Meter's Modbus address and other communication settings (e.g., baud rate) in the inverter's user interface, ensuring they match the Smart Meter's configuration.
- 3
De-energize both the Smart Meter and the inverter, wait for 5 minutes, then re-energize them in sequence (Smart Meter first, then inverter) to reset communication.
- 4
If the message persists, the Smart Meter may require replacement.