Inverter Temperature
Fronius · Symo Advanced
Was bedeutet 301 ?
This status code indicates that the internal temperature of the Fronius Primo GEN24 208-240 inverter is too high. This usually occurs due to insufficient cooling, high ambient temperatures, or a malfunction in the inverter's cooling system, leading to a potential derating or shutdown to prevent damage.
Häufige Ursachen
- Blocked or obstructed air vents on the inverter, impeding proper airflow.
- Ambient temperature at the inverter's installation location is excessively high.
- Insufficient clearance around the inverter, preventing adequate heat dissipation.
- A defect in the inverter's internal cooling fan or thermal management system.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect the inverter's air vents for any blockages, dust accumulation, or debris and clean them if necessary.
- 2
Measure the ambient temperature at the inverter's location and ensure it is within the specified operating limits.
- 3
Verify that there is sufficient clearance (as per manual specifications) around the inverter to allow for proper airflow and cooling.
- 4
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.