Übersetzen...
303
DC module overtemperature
Fronius · Symo Advanced Manual
Was bedeutet 303 ?
The DC power module within the inverter has exceeded its safe operating temperature. This triggers a short-term interruption in energy feeding, and the inverter will then attempt to resume operation once the temperature drops.
Häufige Ursachen
- Restricted airflow to the inverter's cooling elements
- Accumulation of dust or debris on cooling air openings or heat sink
- High ambient temperature exceeding inverter specifications
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Purge the cooling air openings and heat sink to ensure proper airflow.
- 2
If this status code keeps recurring after cleaning, contact your system engineer for further inspection.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fronius Symo Advanced Manual