Grid frequency and power stage set are incompatible
Fronius · Primo GEN24 Operating Instructions
Was bedeutet 454 ?
This code indicates an incompatibility between the detected grid frequency and the configured power stage set. This mismatch prevents the inverter from safely or correctly feeding energy into the grid.
Häufige Ursachen
- Inverter configured for a different grid frequency than the actual connected grid (e.g., 50 Hz vs. 60 Hz).
- Incorrect power stage set installed for the regional grid frequency standard.
- Human error during inverter commissioning.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
If the status code is displayed continuously, notify a Fronius-trained service engineer.
- 2
Verify the inverter's grid frequency settings against the actual grid frequency measurement.
- 3
Ensure the installed power stage set is compatible with the local grid frequency requirements.