Übersetzen...
436

Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced)

Fronius · Primo GEN24 Operating Instructions

Was bedeutet 436 ?

This code indicates a functional incompatibility between one or more PC boards within the inverter, often occurring after a component replacement. This prevents the inverter from operating correctly, but it will attempt to reconnect and resume feeding if possible.

Häufige Ursachen

  • Installation of an incorrect or incompatible PC board during maintenance.
  • Firmware version mismatch between newly installed and existing boards.
  • Hardware revisions not compatible with each other.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Update the inverter firmware to ensure compatibility across all installed PC boards.

  2. 2

    Verify that all replaced PC boards are the correct model and revision for the specific inverter type.

  3. 3

    If the status code is displayed continuously, notify a Fronius-trained service engineer.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fronius Primo GEN24 Operating Instructions