Übersetzen...
327

Fan 2 error

Fronius · Primo GEN24 Operating Instructions

Was bedeutet 327 ?

This code indicates an error with Fan 2, one of the inverter's internal cooling fans. A fan malfunction can lead to insufficient cooling and subsequent overtemperature conditions, causing a short-term interruption in energy feeding.

Häufige Ursachen

  • Fan 2 motor failure or blockage by debris.
  • Faulty fan speed sensor or control circuit.
  • Disconnection of the fan power supply or signal cable.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for fan inspection and replacement.

  2. 2

    Inspect Fan 2 for any visible obstructions or damage.

  3. 3

    Perform an AC reset to attempt to clear transient fan control errors.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fronius Primo GEN24 Operating Instructions