325

Overtemperature in the connection area

Fronius · Primo GEN24 Operating Instructions

Was bedeutet 325 ?

This code indicates an overtemperature condition detected in the inverter's connection area. This suggests excessive heat at the terminals or wiring, causing a short-term interruption in energy feeding before the inverter attempts to restart.

Häufige Ursachen

  • Loose or corroded electrical connections generating localized heat.
  • Overcurrent conditions in the connection area due to faulty wiring or undersized cables.
  • Poor ventilation around the connection terminals.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    If this status code keeps recurring, contact your system engineer for diagnosis.

  2. 2

    Inspect all electrical connections in the connection area for tightness and signs of overheating or damage.

  3. 3

    Ensure adequate clearance and ventilation around the inverter's connection terminals.

  4. 4

    Verify that cabling is correctly sized for the current draw.