Stand-alone operation detected

Fronius · Primo GEN24 Operating Instructions

Was bedeutet 108 ?

This code indicates that the inverter has detected a stand-alone operation condition, meaning it is isolated from the main public grid. The inverter disconnects to comply with grid codes and safety regulations.

Häufige Ursachen

  • Grid conditions indicate an islanding scenario where the inverter is operating independently of the main grid.
  • Malfunction of grid monitoring or anti-islanding protection.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the grid connections for any disconnections that might lead to islanding.

  2. 2

    Verify the anti-islanding function settings within the inverter's configuration parameters.

  3. 3

    If this status code keeps recurring, contact your system fitter or grid operator.