215
TagID Level Sensor Wrong Cell / Defective
Fronius · Perfect Charging
Was bedeutet 215 ?
The level sensor integrated with the TagID module is either mounted in the incorrect battery cell or is defective. This sensor is crucial for monitoring electrolyte levels in specific battery types, such as flooded lead-acid batteries, and ensuring safe operation.
Häufige Ursachen
- Incorrect installation of the TagID level sensor in a battery cell other than the designated monitoring cell.
- An internal failure of the level sensor component within the TagID module.
- Physical damage to the TagID module or its sensor probe affecting its functionality.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the correct mounting position of the TagID level sensor in the specified battery cell according to installation instructions.
- 2
Perform diagnostics on the TagID module, if available, to confirm the functionality of the level sensor.
- 3
Replace the TagID module if the level sensor is integrated and found to be defective.