Übersetzen...
208

TagID Battery Master Data Invalid

Fronius · Perfect Charging

Was bedeutet 208 ?

The essential battery master data stored in the TagID module is either invalid or not available. This data is fundamental for the charger to properly identify the battery, apply correct charging algorithms, and ensure safe operation.

Häufige Ursachen

  • Corrupted or accidentally erased master data within the TagID memory.
  • The TagID module was incorrectly programmed or was not programmed at all during manufacturing or setup.
  • A faulty memory chip within the TagID module.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Attempt to reprogram the battery master data into the TagID module using appropriate service tools and software.

  2. 2

    Verify that the TagID programming process was completed successfully and that the data is now readable.

  3. 3

    If data cannot be restored or rewritten, the TagID module may be defective and require replacement.

Alle Codes in diesem Handbuch durchsuchen (61)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes