Übersetzen...
12
Grid Phase Failure
Fronius · Perfect Charging
Was bedeutet 12 ?
This fault indicates an issue with the electrical grid connection, specifically a detected phase failure. This can prevent the battery charger from operating correctly or initiating a charging process, especially in three-phase systems.
Häufige Ursachen
- Loss of one or more phases in the multi-phase power supply to the charger.
- Significant voltage imbalance or drop in one or more phases.
- An issue with the electrical infrastructure supplying power to the charger.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify all incoming phases at the charger's input terminals using a multimeter to confirm voltage presence and balance.
- 2
Inspect the main circuit breaker and associated fuses for the charger's power supply for trips or blown conditions.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fronius Perfect Charging