Inverter: IPM alarm (OH) (N axis)
Fanuc · Series 30i CNC
Was bedeutet A. ?
An Intelligent Power Module (IPM) overheat alarm has occurred for the N-axis. This indicates the IPM for the N-axis is operating at an excessively high temperature. This typically results from the motor being used under harsh conditions (e.g., heavy load) or a high ambient temperature around the SVM.
Häufige Ursachen
- The motor is being used under a harsh condition.
- The ambient temperature is high.
- SVM failure.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the motor load for the N-axis is within its rated specifications.
- 2
Measure the ambient temperature around the SVM.
- 3
Verify adequate airflow to the SVM's heat sink and cooling components for the N-axis.