ILLEGAL MACHINE POS.(SV)
Fanuc · Alpha i Series Servo Amplifier
Was bedeutet SV0477 ?
The servo detected that the machine position on the axis is not within the safety area (parameter No.13831 to 13838) during safety monitoring (when the safety check request signal (*VLDVx) is 0). This indicates the axis moved outside its defined safe operating envelope after the machine reference position was established, which can lead to collisions or unsafe conditions.
Häufige Ursachen
- Machine reached an unexpected position due to external forces or incorrect command.
- Axis limit switch triggered unexpectedly during movement.
- Following error too large, exceeding P1-54.
- Incorrect homing sequence or lost position reference.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Confirm that parameters No.13831 to 13838 define the correct safety area for the machine.
- 2
Verify that the axis operation program ensures movement is performed within the established safety area.
- 3
Ensure the machine reference position has been correctly established for the affected axis.