SV0474

EXCESS ERROR (STOP:SV)

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet SV0474 ?

The servo detected that the positional deviation during stopping exceeded the parameter (No. 1839, No.1842) setting value. This indicates a failure of the axis to hold its commanded stop position within tolerance, potentially due to mechanical issues or incorrect tuning.

Häufige Ursachen

  • The position error has become excessively large during a stop command.
  • The servo drive failed to reach the commanded stop position within tolerance.
  • A sudden mechanical load or external force caused significant position deviation.
  • Parameter P500.1 (Position Error Limit) is too small for the stop maneuver.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the values of parameters No. 1839 and No.1842, which define the allowable positional deviation during stopping.

  2. 2

    Inspect the mechanical brake for proper operation and wear on the affected axis.

  3. 3

    Check for external forces, excessive load, or increased friction that could cause unexpected movement while stopped.