Übersetzen...
SV0381

ABNORMAL PHASE (EXT)

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet SV0381 ?

An abnormal alarm in the position data occurred on the separate linear scale. This indicates an issue with the phase signal generation or detection from the external linear scale.

Häufige Ursachen

  • Signal degradation or noise affecting the phase signals of the external linear scale.
  • Physical damage or contamination on the external scale's reading head.
  • Malfunction in the external scale's signal generation circuitry.
  • Incorrect installation of the external scale, causing phase shift.
  • Encoder signal processing fault within the servo drive.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Clean the external scale's reading head and scale surface.

  2. 2

    Measure phase signal levels from the external scale's output terminals.

  3. 3

    Verify correct installation and alignment of the external scale.

  4. 4

    Check servo parameter P1-04 (External Encoder Type) for correct selection.

  5. 5

    Inspect external scale for any visible damage to the track or head.

Alle Codes in diesem Handbuch durchsuchen (101)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Alpha i Series Servo Amplifier