Übersetzen...
SV0307

APC ALARM: MOVEMENT EXCESS ERROR

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet SV0307 ?

The machine moved excessively, leading to an inability to obtain the correct machine position. This suggests unexpected or uncontrolled motion of the axis.

Häufige Ursachen

  • Machine has moved beyond expected limits during an operation.
  • External force applied to the machine axis.
  • Servo control loop is unstable, causing oscillation.
  • Incorrect limit switch configuration or activation.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify actual axis position against expected position limits.

  2. 2

    Inspect machine for any signs of collision or external impact.

  3. 3

    Review servo tuning parameters (e.g., P3-XX) for stability.

  4. 4

    Confirm limit switch settings and functionality.

Alle Codes in diesem Handbuch durchsuchen (101)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Alpha i Series Servo Amplifier