SP9070
ILLEGAL AXIS DATA
Fanuc · Alpha i Series Servo Amplifier
Was bedeutet SP9070 ?
The spindle detected a mismatch between the spindle amplifier connection state and its hardware setting. This alarm can be issued if the spindle amplifier configuration has been changed without corresponding software updates or if there is a wiring issue.
Häufige Ursachen
- Invalid or inconsistent axis data within the system's memory.
- Mismatch in motor encoder counts or resolutions.
- Configuration parameter for axis type or limits is incorrect.
- Data corruption related to axis calibration.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the physical connection state of the spindle amplifier.
- 2
Verify the spindle amplifier hardware settings for correctness.
- 3
If the spindle amplifier configuration was recently changed, correct the settings on the spindle amplifier side to match the actual configuration.