Übersetzen...
PW0012

USER I/O CROSS CHECK ERROR(DCS PMC)

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet PW0012 ?

The DCS PMC detected an error in the user-defined safe I/O cross-check function. This indicates a discrepancy in the monitored user-configured safe I/O signals, potentially affecting user-implemented safety features. A power cycle is required.

Häufige Ursachen

  • DCS PMC detects inconsistency in user-defined safe I/O signals.
  • Faulty user-programmed input or output device influencing safe I/O.
  • DCS PMC internal error in comparing user-defined safe I/O states.
  • Signal noise or interference on user-defined safe I/O lines.
  • Incorrect configuration of user-defined safe I/O within the DCS PMC.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the status of all user-defined safe I/O signals on the DCS PMC.

  2. 2

    Measure signal voltage at the DCS PMC user I/O terminals.

  3. 3

    Verify parameter P1-18 (DCS PMC User I/O Configuration) for correct settings.

  4. 4

    Inspect the wiring and connections of all user I/O devices.

  5. 5

    Review user-defined logic that controls or monitors these I/O points.

Alle Codes in diesem Handbuch durchsuchen (101)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Alpha i Series Servo Amplifier