10016
Runaway Detection Parameter Overflow
Fanuc · Alpha i Series Servo Amplifier
Was bedeutet 10016 ?
This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to runaway detection has overflowed. This suggests an issue with the runaway detection function's configuration, leading to computational errors.
Häufige Ursachen
- The parameter used for runaway detection has overflowed its valid range.
- An internal calculation for runaway detection exceeded the maximum value.
- Parameter P100.1 (Runaway Threshold) is set excessively high.
- Sensor data used for runaway detection is abnormally large.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Disable the runaway detection function by setting bit 0 of parameter 1740 (Series 15) or 2200 (Series 16, etc.) to 1.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026