Übersetzen...
0544

Dead Zone Compensation Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet 0544 ?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.

Häufige Ursachen

  • Dead zone compensation parameter calculation has overflowed.
  • System unable to effectively compensate for nonlinearities.
  • Parameter for dead zone estimation (P04-12) is too aggressive.
  • Significant backlash in gearboxes or couplings.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.

Alle Codes in diesem Handbuch durchsuchen (101)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Alpha i Series Servo Amplifier