0534

Dead Zone Compensation Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet 0534 ?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.

Häufige Ursachen

  • Dead zone compensation parameter calculation has overflowed.
  • Issues with compensating for mechanical backlash or friction.
  • Incorrect dead zone compensation setting (P04-12).
  • Stiction or high static friction in the system.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.